Ethanol Conference

Canadian Greenhouse Conference

Southeast BioEnergy

FEED WATER SYSTEMS : OXY-MISER : SPECIFICATION DATA CHART

The Oxy-Miser is guaranteed to Remove Oxygen in Boiler Feedwater to .005cc/liter. Removes carbon dioxide as well as oxygen.

DEAERATOR SPECIFICATIONS (ALL DIMENSIONS ARE IN INCHES)
  OXY-MISER MODEL NO. OM-5 OM-7 OM-10 OM-12 OM-14 OM-16 OM-19 OM-22 OM-26  
  WEIGHT TANK/TRIM LBS 2400 2400 2700 2700 3000 3000 4000 4000 4500  
CAPACITY   LBS/HR 5,000 7,000 10,000 12,000 14,000 16,000 19,000 22,000 26,000
WATER CAPACITY @ OVERFLOW GAL 268 268 331 331 456 456 789 789 957
WATER CAPACITY @ NWL GAL 118 118 141 141 189 189 285 285 347
WATER CAPACITY (W/DOME) FLOODED GAL 354 354 424 424 565 565 877 877 1033
A TANK DIAMETER   IN 42 42 42 42 42 42 48 48 48 A
B TANK LENGTH   IN 48 48 60 60 84 84 96 96 120 B
C OVERALL LENGTH BARE VESSEL IN 70 70 81 1/2 81 1/2 105 105 118 118 142 C
D SUPPORT STAND LENGTH   IN 46 46 54 54 72 72 84 84 96 D
E SADDLE WIDTH   IN 36 36 36 36 36 36 42 42 42 E
F STEAM INLET 150#-FLNG IN 4 4 4 4 6 6 6 6 6 F
G WATER OUTLET 150#-FLNG IN 3 3 3 3 4 4 4 4 6 G
H TANK DRAIN   IN 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 2 2 2 H
I OVERFLOW   IN 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 I
J CONDENSATE RETURN   IN 2 2 2 2 2 1/2 2 1/2 3 3 3 J
K INLET WATER   IN 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 K
L DOME DIAMETER   IN 12 12 12 12 14 14 16 16 16 L
M STEAM PURGE VENT   IN 3/4 3/4 3/4 3/4 1 1 1 1 1 M
N TANK HEIGHT FROM SUPPORT IN 66 66 66 66 72 72 76 76 76 N
O BASE OF SADDLE TO C/L OF TANK   IN 27 27 27 27 29 29 30 30 30 O
P C/L TO OVERFLOW   IN 7 1/2 7 1/2 9 9 9 9 9 1/2 9 1/2 9 1/2 P
Q HD. TO VENT CONNECTION   IN 24 24 30 30 42 42 48 48 60 Q
  OXY-MISER MODEL NO. OM-5 OM-7 OM-10 OM-12 OM-14 OM-16 OM-19 OM-22 OM-26  

DEAERATOR SPECIFICATIONS (ALL DIMENSIONS ARE IN INCHES) - CONTINUED
  OXY-MISER MODEL NO. OM-30 OM-35 OM-40 OM-50 OM-60 OM-80 OM-100 OM-125 OM-150 OM-200  
  WEIGHT TANK/TRIM LBS 4500 4750 5700 7300 8000 8800 9500 10500 11500 14000  
CAPACITY   LBS/HR 30,000 35,000 40,000 50,000 60,000 80,000 100,000 125,000 150,000 200,000
WATER CAPACITY @ OVERFLOW GAL 957 1025 1224 1600 1931 2421 2717 3810 4354 5796
WATER CAPACITY @ NWL GAL 347 365 444 560 679 848 954 1324 1517 1998
WATER CAPACITY (W/DOME) FLOODED GAL 1033 1091 1305 1673 2022 2521 2832 3935 4499 5956
A TANK DIAMETER   IN 48 54 54 66 66 72 72 84 84 96 A
B TANK LENGTH   IN 120 96 120 96 120 126 144 144 168 168 B
C OVERALL LENGTH BARE VESSEL IN 142 123 1/2 147 1/2 126 1/4 148 1/4 156 174 179 203 207 C
D SUPPORT STAND LENGTH   IN 96 84 102 84 108 108 120 132 128 132 D
E SADDLE WIDTH   IN 42 48 48 56 56 60 60 66 66 78 E
F STEAM INLET 150#-FLNG IN 6 6 6 8 8 10 10 10 10 10 F
G WATER OUTLET 150#-FLNG IN 6 6 6 6 6 6 6 8 8 8 G
H TANK DRAIN   IN 2 2 2 2 2 1/2 2 1/2 2 1/2 2 1/2 3 2 1/2 H
I OVERFLOW   IN 2 2 2 3 3 3 3 3 3 6 I
J CONDENSATE RETURN   IN 3 3 3 4 4 4 4 6 6 6 J
K INLET WATER   IN 1 1/2 2 2 2 2 2 2 2 1/2 2 1/2 4 K
L DOME DIAMETER   IN 16 18 18 20 20 20 20 24 24 30 L
M STEAM PURGE VENT   IN 1 1 1 1 1 1 1 1 1 1 M
N TANK HEIGHT FROM SUPPORT IN 76 86 86 101 101 111 111 124 124 135 N
O BASE OF SADDLE TO C/L OF TANK   IN 30 35 35 41 41 44 44 50 50 56 O
P C/L TO OVERFLOW   IN 9 1/2 11 3/4 11 3/4 16 16 16 16 17 17 24 P
Q HD. TO VENT CONNECTION   IN 60 51 60 48 60 60 72 72 84 84 Q
  OXY-MISER MODEL NO. OM-30 OM-35 OM-40 OM-50 OM-60 OM-80 OM-100 OM-125 OM-150 OM-200  
NOTE: STAND HEIGHT IS DEPENDENT ON NPSH OF PUMP REQUIRED • DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE, CERTIFIED DRAWINGS AVAILABLE UPON REQUEST • CONSULT FACTORY FOR LARGER SIZES.

Back to Previous Page
 
Copyright © 2006 Hurst Boiler & Welding Company, Inc. • Website Design and Development by Accurate Imaging, Inc.Terms & ConditionsWebmasterIntranet • Last Updated 07/06