Euro Series Boilers

THREE-PASS

SCOTCH MARINE DESIGN

LOW PROFILE, WET BACK CONSTRUCTION

Available in 8 Models from 100 - 2000 BHP

Steam Pressures to 15-300 PSI

Hot Water Section I and Section IV

Euro Series Boilers
Horsepower:

100-2,000 HP

MBTU/HR:

3,348-66,950 MBTU/HR

Steam To:

300 PSI

Hot Water To:

60 PSI

Wetback design eliminates refractory rear door & baffles between flue gas passes

  • Natural Gas
  • Oil
  • Combination
  • Steam
  • Hot Water

Standard Features

  • Boiler is of the three-pass, scotch type, built and stamped in accordance with the requirements of the ASME Code, and listed by the National Board of Boilers and Pressure Vessel Inspectors.
  • Large combustion chamber with low heat release for complete combustion. Smoke box is rear-mounted with slip-on stack connector.
  • Access to fireside is accomplished with hinged and davited front and rear doors. Flame observation ports are located on front and rear.
  • Openings for vessel cleanout and inspection of waterside are provided with 3" x 4" hand holes, and 12" x 16" manway access.
  • Insulated with 2" high density mineral wool, lagged with 22 gauge grip jacketing, baked on finish to resist chipping and fading.
  • Firetubes are rolled and beaded on power boilers, expanded and flared on low pressure boilers.
  • Supports include lifting lugs securely welded to the top of shell; structural steel support legs on skids support the boiler so that special foundations are not required.

Standard Steam Trim

  • Operating & high limit pressure control
  • Modulating pressure control (when applicable)
  • Water column with gauge glass, combination low water cut-off & pump control
  • Probe Aux, L.W.C.O. Steam pressure gauge, syphon & test cock
  • Water column drain valve
  • Safety relief valve(s) per ASME Code

Standard Water Trim

  • Operating & high limit temperature control
  • Modulating temperature control (when applicable)
  • Probe type low water cut-off control
  • Combination pressure & temperature gauge
  • Hot water return baffle for shock resistance
  • Safety relief valve(s) per ASME Code

Boiler Design

Three-Pass "Scotch Marine" Firetube design with stress relieving "Wetback" construction. Pressure designs for steam are 15-300 psi. 100-600 hp. 250 psi. max. for 700-1500 hp. and 200 psi. max. for 1800-2000 hp. Hot Water pressures models are from 30-160 psi. High pressure, high temperature Section I hot water boilers available. Factory assembled with trim, tested, ASME code, UL, and CSD-1 standards.

Steam Model Trim

Safety relief valve, operating pressure control, high limit pressure control with manual reset, steam pressure gauge with syphon, combination pump control and low water cut-off with gauge glass assembly and drain valve, auxiliary low water cut-off with manual reset.

Hot Water Model Trim

Safety relief valve, operating temperature control, high limit temperature control with manual reset, combination pressure & temperature gauge, low water cut-off control with manual reset. BURNER: Matched UL listed "forced draft" power burners with factory prepiped, wired and tested fuel configurations for natural gas, propane (LP) gas, No. 2 (diesel) oil, or combination of both gas/oil.